NavePoint’s shallow 1U shelf fits rail spacing from 13.8 to 20.8 inches. NavePoint listing Tecmojo’s 27.6-inch 1U shelf fits 19.7 to 37.4 inches and lists a 242 lb load limit. Tecmojo catalog StarTech describes the ADJSHELF as an adjustable-depth rack shelf. StarTech product page
Mounting depth, tray depth and load limits
Use the mounting range to check the distance between the rack’s front and rear rails. Use the tray depth to check the front-to-back footprint your equipment needs.
| Shelf | Listed mounting range | Tray depth | Published load limit | Steel | Manufacturer |
|---|---|---|---|---|---|
| NavePoint shallow shelf | 13.8 to 20.8 in | 13.8 in | 242 lb | Cold-rolled steel | NavePoint listing |
| Tecmojo 27.6-inch shelf | 19.7 to 37.4 in | 27.6 in | 242 lb | Tecmojo catalog |
Check your rack and equipment
Confirm that the rack has four posts, 19-inch mounting and a free rack unit. Then check the fit at the height where the shelf will sit.
- Measure the rail spacing. Measure horizontally from the front face of the front rail to the rear face of the rear rail. Oracle rackmounting guide Keep shelves whose mounting range includes that distance.
- Check the equipment footprint. Compare the front-to-back footprint that needs support with the tray depth. Oracle’s cabinet planning guide allows space behind servers for cabling. Oracle rackmounting guide In an enclosed rack, check that the tray and equipment fit inside the cabinet with room for their cables.
- Check both load limits. Add up the weight of everything going on the tray and compare it with the shelf’s published limit. Check the combined weight of mounted equipment against the rack’s load rating. Oracle rackmounting guide Include the shelf when adding up what the rack will hold.
Worked example. Suppose the rails are 20 inches apart and the equipment needs 26 inches of tray depth and weighs 190 lb. Both listed mounting ranges include 20 inches. NavePoint’s 13.8-inch tray is too short. Tecmojo’s 27.6-inch tray and 242 lb shelf limit clear the depth and load checks.
Evidence and limits. The manufacturers’ shelf listings and Oracle’s Sun Fire V445 rackmounting guide were checked on November 27, 2026. No hands-on testing was performed for this guide.